American Audio COMMANDER PLUS - REV 1-2 Betriebsanweisung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
UG-196-02-C
196-02-C - DA7322 Audio Codec with DSP
User guide UG-196-02-C
Revision 0.6
15-September-2014
CFR0011-121-00 Rev 1
13 of 21
© 2014 Dialog Semiconductor GmbH
Status and controls 6.3
Polling Enabled By default the current page of device
register content is updated via polling the I2C interface. If
disabled, these read-backs are suppressed. This is used to
force the communication over the bus to be silent. If this is set
to automatic, the program will only poll the device while the
application is the topmost window. If obscured by another
program or window, polling will be disabled.
LED If the device is active this LED is green. If
the LED is red the device is inactive
Interface Selects between SAM3U I2C/SPI control and
offline mode. Switching to offline, then back to SAM3U
I2C/SPI reinitialises the USB interface. I2C mode is the default
communication setup for the device
USB OK? Solid green illumination indicates that the USB is
OK and communicating.
Stop Program This terminates the program. If there are
unsaved changes, a dialog box is displayed.
Read Chip ID This reads the Chip ID from the device
and displays the content in the text box above the button. The
text box indicates the device version when the device is
active. When inactive, version status will not be correct.
Load Loads previously saved text files, sends loaded
register values in file and reads back all registers from device.
Selecting ‘Load’ opens a list of other options related to loading
files. Select ‘load codec file ..’ to bring up a dialog box which
allows you to select, view, copy or re-name files. Once a file
has been selected, ‘Load codec file..’ opens the file and
executes commands listed in the file to manipulate the
registers of the device allowing the device to be quickly
configured for different setups with a script file. Load codec file
should always be used when using audio based devices, Load
is used for non-audio based device configuration.
Save Saves the current panel state to a text file.
Selecting ‘Save Codec file..’ saves the codec registers in a
text file with sequential register address number, value of
register and name listed in the file. Selecting ‘Register Dump’
option saves the current register values to a text file in a
slightly different format, the register name and value of
register are shown in the file content. See Appendix A for
further details. Save Codec should be used when using audio
based devices.
Note 3 The difference between Save and ‘Register Dump’ is that the
Save option dumps the contents of all panel controls to the file
(a save state operation); whereas, ‘Register Dump’ reads the
device contents (including status registers) into the file. Also
some codec registers do not have read-back capability.