American Audio COMMANDER PLUS - REV 4-5 Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
MCP 1000 • Operation
Operation, cont’d
3-4
MCP 1000 • Operation
3-5
Video switcher — SIS command: i&
This confi guration is the same as for the audio-video switcher
shown on the previous page, except that only video signals are
switched. This is called "audio breakaway."
Audio switcher — SIS command: i$
This confi guration is the same as for the audio-video switcher,
except that only audio signals are switched. This is called
"audio breakaway."
Audio breakaway is not available in matrix mode.
In the illustration below, the master switches video only and the
slave switches audio only. In this confi guration, the two units
are operationally identical, even though one is a master and one
is a slave. The master could have been set for audio, and the
slave could have been set for video.
MCP 1000 Master
MCP 1000
MENU NEXT
RS-232 Control
MCP 1000 Slave set for Switcher
MCP 1000
MENU NEXT
MCP 1000M, MCP 1000S, and System 10 Plus
Output (matrix) — SIS command: i*o!
Depending on the size of the matrix switcher, the MCP 1000 can
be set up for one of 64 output numbers. In output mode, an
MCP 1000 acts like a switcher for a specifi c output number on
the matrix. For example, if the MCP 1000 is set up for output 5
and panel button 3 is pressed, the matrix ties input 3 to output 5.
Preset (matrix) — SIS command: p.
A preset is a set of ties, inputs to outputs, that has been made
and stored previously. Depending on the size of the matrix
switcher, the MCP 1000 can be set up for presets 1 through 16,
or 17 through 32. Pressing an MCP button recalls (activates) a
preset in the matrix.
AUDIO
VIDEO
I/O
CONTROL
ENTER PRESET
VIEW
ESC
INPUTS
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
13
1
2
3
4
5
6
7
8
9
10
11
12
OUTPUTS
14
15
16
13
AV MATRIX SWITCHER WITH IP LINK™
MAV PLUS SERIES
MCP 1000 Master set for Presets 1-16
MCP 1000
MENU NEXT
MCP 1000 Slave set for Output 1
MAV Plus 1616 A (Matrix)
using MCP 1000s
MCP 1000
MENU NEXT
RS-232
Control
Comm-Link
Control
Next (more MCP 1000s or MKP 1000s)
Output mode and preset mode on a MAV Plus 1616 A
Slave applications (comm-link)
CAUTION
Do not connect both a Matrix 3200/6400 BME
and an MCP 1000M (master) unit on the same
comm-link connection. Also, do not connect more
than one master on the same comm-link connection.
Both of theses units supply voltage to the comm-
link ports on pins A and B. Connect these pins
to only one power source. This does not apply to
MCP 1000S (slave) units.
A slave unit has no RS-232 port; it communicates through
the comm-link ports. This allows it to be used in a
Matrix 3200/6400 system, either as a single control panel or with
other MCP 1000 and MKP 1000 units.
An MCP 1000S must always connect to an MCP 1000M or to a
Matrix 3200/6400 BME. See "Output (matrix) — SIS command:
i*o!" and "Preset (matrix) — SIS command: p.", earlier in this
chapter, for two examples of slave units used with a master unit.
A slave sends signals by comm-link to the MCP 1000M or BME.
An MCP 1000M translates those signals to SIS commands and
sends them to the controlled device. A master BME sends
control signals to the appropriate BMEs in the Matrix 3200/6400
system.
Daisy-chain confi guration
A daisy-chain confi guration saves cable by allowing signals
from units that are far away to be passed serially through units
that are near the master unit. MCP 1000 and MKP 1000 units
can be mixed in the same confi guration.
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 20 21

Kommentare zu diesen Handbüchern

Keine Kommentare