METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-121 Revision 4 : 05/09/12
Metro Baseline Re-Baseline: 04/29/10
complete fast enough to not drop any active telephone call. All equipment
comprising the CTS shall have carrier class reliability.
2. Voice and Data on the CTS shall operate on the fiber optic transmission
service at a bit rate capable of transmitting the type and quantity of signals
required without impeding the operation of the LRT or HRT System. The
CTS shall provide voice grade channels for telephone, public address audio,
radio audio and control, and data channels for the SCADA, UFS and other
subsystems. Bandwidth and quality of service shall be allocated in
accordance with the specific subsystem requirements.
3. The Metro private telephone system shall have dual paths within the carrier
multiplex subsystem. Loss of a fiber optic line or repeaters shall cause the
remote multiplex unit to switch to the redundant transmission link.
4. CTS repeaters shall be located so that maintenance functions can be
performed safely without affecting normal operations.
5. Full featured CTS management tools shall be included that allow system
configuration and alarms to be managed from a single remote location.
Maintenance and diagnostic capabilities shall be provided at each local
node.
C. Design Criteria
1. The CTS shall consist of, but not be limited to, the following components:
a. Transmission Lines (cable and fibers)
b. Transmission Line repeaters and housing
c. Transmission line termination apparatus
d. Transmission line supervision with automatic transfer apparatus may be
either internal or external optical equipment.
e. T-Carrier and FT-Carrier or SONET Equipment with the following
MINIMUM Functions:
1) Common Logic Redundancy
2) Power Supply Redundancy
3) Output Redundancy (Either Constant or Hot Standby for optical
equipment.
4) Remote Alarm Annunciation
5) At ROC, dual redundant nodes shall be provided.
f. Mounting Racks and Cabinets
g. Duct Liners
h. Voice Frequency Patch Panels
i. Fiber Optic Patch Panel
j. Network switching and routing equipment
2. Electro-optic Modulators or Optical Transmitters (sources), converting an
electrical signal input to an optical signal by modulating a light source, shall