METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-128 Revision 4 : 05/09/12
Metro Baseline Re-Baseline: 04/29/10
installations shall be inconspicuous and not easily identifiable to the general
public.
a. The key card shall contain a machine-detectable code indicating unique
security classification number (SCN). When an employee uses a key
card to activate a card reader adjacent to a controlled door, the
subsystem shall release the electric lock if access is authorized for the
specific card, based upon door number, time of day, and day of the
week.
b. The subsystem shall maintain a record on magnetic disk. The record
shall include intrusion alarms, diagnostic alarms, all card reader events
and authorization status. The date, time, location, card identification,
card holder's name, department badge number and SCN shall be
recorded with each record. These records shall be retrievable via both
CRT screen and hard copy. Functions for archiving and restoring
records shall be provided,
c. The IDS server at ROC shall be a pair or computers operating in
primary/standby configuration with automatic failover. All system
configuration and alarm/event data shall reside on RAID protected
shared disk memory.
d. If the subsystem fails or is out of service due to a communications loss
with the IDS server, its functions shall transfer to a backup mode of
operation. While the backup mode is in effect, access to a door shall be
granted when a zone code ascribed to the security classification number
on a card coincides with the zone code assigned to the door where the
card is presented.
e. If both the subsystem and its backup mode fail, door releases shall be
effected from a remote terminal. In the event of a total failure, a
mechanical means of activating door releases for exiting through the
controlled doors shall be provided. This provision shall allow the
preselection of the appropriate failure mode, be it locked or unlocked, for
each specific door.
f. The controlled access or intrusion detection system shall not inhibit
egress.
g. The subsystem shall provide the capability of authorizing and voiding a
single SCN or a group of SCNs. The subsystem shall provide the
capability of assigning employee names, department, badge numbers
and zone codes to each SCN. The subsystem shall provide the
capability of authorizing combinations of door numbers, SCNs, times of
day, and days of the week. The subsystem shall prevent alterations of
the data by unauthorized persons and provide capability for changing
access codes and validations on a real-time basis.
h. The subsystem shall provide selection capability to print out authorized
access and/or print out only rejected access attempts.