METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-11 Revision 4: 05/09/12
Metro Baseline Re-Baseline: 04/29/10
Emergency Swing Gates and Fencing used in fare barriers shall be 5 ft. in height
and be of stainless steel construction for underground stations and painted steel
construction for other than underground stations.
TVM locations shall allow for front TVM door swing opening at least 130
degrees, based on door being full width of machine and hinged on the left side
of cabinet. SAV locations shall allow for top cover swing opening at least 130
degrees, based on the angled cover being full width and depth and hinged at the
top back side of the cabinet. This shall be considered in locating fare collection
equipment near support columns, trash enclosures, and other vertical elements
in the station design.
TVM and SAV locations shall account for patron sight distances of trains and
vehicles at intersections.
The maximum dimensions of each TVM are 36” wide x 25” deep x 74” high
(76.2” to top of fan shroud). The maximum dimensions of each SAV are 14”
wide x 7” deep x 43” high. An additional side clearance of 12” minimum, back
clearance of 6” minimum, and front clearance of 48” minimum shall be provided
for the TVM. SAVs shall be sited with 14” side parallel to patron flow across the
paid/non-paid boundary, have a back-to-back clearance of at least 4” and have
a minimum front-to-front clearance of at least 48” for ADAAG compliance.
Side clearance is required for patron queuing space, ADAAG clear space,
equipment installation, and for opening the doors of the machines for
maintenance and service. If TVMs/SAVs are grouped such that two or more
machines are side-by-side in a grouping, the external side clearance needed to
either external side of the grouping shall be 6” for TVMs and 8” for SAVs. These
space requirements shall be taken into account when locating TVMs or SAVs
near support columns, trash enclosures, and/or other vertical elements in the
station design.
Canopy coverage shall be provided for TVMs, fare gates, and SAVs for
protection of equipment when it is opened for maintenance and revenue
servicing during inclement weather. This will also provide weather protection for
passengers using the equipment.
B. Basic Provision Requirements
1. Equipment Pad – TVMs, Fare Gates and SAVs
TVMs, Fare Gates, and SAVs will be designed for outdoor installation and
be freestanding, suitable for mounting to finish surface using anchors at the
four corners within the base of each equipment cabinet type.
The minimum concrete slab thickness in area for mounting TVMs, fare
gates, and SAVs shall be at least 8” throughout footprint of the device,
extending at least 12” beyond the footprint perimeter to allow for drilling and
setting anchors. Station platform slopes at equipment location shall be
limited to a maximum of 2% transverse and 2.4% longitudinal. The pad