METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-74 Revision 4 : 05/09/12
Metro Baseline Re-Baseline: 04/29/10
stored within a logical process, sampled as digital or analog inputs, or produced
as digital or analog output, shall result in a safe system state.
Non-vital circuits may use non-vital relay or solid-state technology. Failures of non-vital
equipment shall not affect the safety of the system. Non-vital systems shall interface with
vital systems in a manner, which isolates the vital systems from malfunctions of the non-vital
systems.
Vital microprocessor systems may be used.
The use of radio, land cable, or any combination, which forms a serial communication
channel for the signal system, shall not be considered vital in itself. Design techniques shall
be employed such that the equipment at each end of the communication link shall be
capable of detecting errors in the data transmitted and received, such that system operation
remains safe.
9.4.4.16 Materials and Equipment
9.4.4.16.1 General
Assemblies and components used to perform identical functions within the system shall be
mechanically and electrically interchangeable. Standard commercially available equipment
and material from multiple sources shall be used where practicable.
All wayside equipment shall be secured and protected by the use of tamper-resistant
covers. Where deemed appropriate by the Designer, further protection shall be provided
with intrusion detection devices.
All cables and wires shall be suitably protected. Conduits shall be provided under tracks,
along bridges and through roadways, to meet AREMA recommendations. All material and
equipment furnished shall be new and standard products of manufacturers regularly
engaged in the production of like equipment, and shall be the latest design, which complies
with the requirements of these Contract Documents.
9.4.4.16.2 Equipment Location
Signal equipment shall be located along the wayside only where necessary. All other
equipment shall be located on the outer edge of the right-of-way, in easily accessible
equipment housings.
Signal houses shall be provided with a fire and intrusion detection system.
Signal masts, grade crossing gates, flasher masts, cantilever signal masts and all concrete
signal structures shall follow CPUC GO 75 and City requirements for these structures.
9.4.4.16.3 Equipment Housings
All signal equipment housings shall include all required environmental controls to facilitate
maintenance and operation, including any necessary heating, ventilation and air
conditioning. The signal equipment shall be capable of operation in the event of a failure of
any environmental control subsystems. Houses, cases and junction boxes shall be steel or
aluminum. Signal houses and cases containing electronic equipment shall be coated with