METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-93 Revision 4 : 05/09/12
Metro Baseline Re-Baseline: 04/29/10
2. Within each Communications subsystem for each segment, like functions
shall be performed by identical units. In no case shall the apparatus or
hardware used in one portion of a segment's subsystem be different from
that used in another portion to perform the same function under similar
operation and environmental conditions. Due to technological
advancements, parts availability and other restrictive factors functional
equivalent equipment may be used between segments.
3. Modular design shall be employed. Electrical and mechanical components
shall be organized in cabinet-mounted plug-in assemblies. The mixing of
equipment associated with two subsystems in one plug-in assembly shall not
be permitted. Apparatus serving similar functions shall be in the same
relative location in all cabinets, wherever practicable.
4. Cabinets, racks and battery racks shall be protected to seismic codes of the
State of California as applicable.
5. All communications equipment located in the passenger stations, wayside,
ROC and the Yards and Shops shall be powered from un-interruptible power
sources or DC back-up battery systems.
6. All communications equipment shall be clearly stenciled such that the
nomenclature is visible from the front with the normal operating covers on
the devices.
a. All multiplexer's channel banks, cross-connect panels, jackfields, fiber
optic patch panels, fiber splice trays, power supplies, frame blocks,
protector blocks, shall be stenciled in a manner that is visible to a person
standing in front of the device.
1) All multiplexer's and channel banks shall be stenciled to show
system identification and the distant terminal that makes up the
system.
2) All cross-connect panels and jackfields shall be clearly stenciled as
to what equipment or channels are appearing on the jackfields.
3) All fiber optic patch panels shall be clearly stenciled on the non
removable portion of the shelf and on the front cover whether
removable or not as to the cable number, the route, and where the
cable goes or distant end.
4) All other equipment, as a minimum, shall be stenciled on the front
cover as to what the device is.
5) All cable terminations shall have cable tags identifying the cable
number, the number of copper pairs or fiber strands in the cable, the
distant end (where the cable goes). Cable identification shall match
with the as built drawings.
6) All blocks and Protectors terminating cables shall be stenciled on the
front of the block with the cable number, the number of pairs in the