DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, info@dccspecialties.com www.dccspecialties.com 1 of 10
The PSX
-
1,2,3,4 Series (Rev:J, 5/11)
Intelligent, DCC, Solid State Circuit Breakers with
Integrated Block Detection and Feed Back
Quick Start: see Pg
-
13, Test Before Installing,
A
ll Programming is Optional
!
Designed by Larry Maier Developed by DCC Specialties US Patent 7,810,435
The Power Shield X series is a product of years of research into problems
dealing with false over load that cause premature shut do wn of DCC Boosters and
other Ci rcuit Breake rs. These false ov erloads are caused by large cap acitors used
in sound systems decoder s or ligh ted pa ssenger cars. The ove rload appear s as a
short circuit until the capacitors are charged. The logic on the n ew P ow er S hi eld X
Series determ ines i f th e load is a t rue short o r jus t an over load d ue to di scharged
capacitor.
Versions Available:
PSX
-
1OneOutput, PSX
-
2 Two Outputs, PSX
-
3 Three O utputs, PSX
-
4 Four Outputs
:
A
ll Solid State Operation: Fast, solid st ate design w ith reliable quiet
action….no clicks or sparks.
A
daptive Load R eset: Electronically determines if the overload is a real short or due to excess
capacitance in sound decoders or lighted passenger cars.
Boost for Low Power Systems: Some low p ower DCC Systems boosters need a boost w hen resetting.
Adding this jumper helps res et low pow er output systems.
A
uto Stop w ith C V Reset: A pho toc el l i npu t c an d ete ct a train in th e re ve rse sec t ion and tu rn off power. A DCC
command can then restor e the pow er.
Block Detection: Either a photo cell or cu rrent can be used to detect a train in a block. The p hotocell
can turn off the block.
A DCC command can then restore the pow er.
Over Voltage Protection: If t here is an over voltage on th e track caused by a DCC System
failure or other power inputs the PSX w ill shut down and protect decoders
Wide Range of Current Trip Setting: The currents can be adju sted over a range of 1.27 to 17.8 amps.
Values can be set eit her w ith CV settings or Jumpers.
Very Low Volt age Drop: Breaker On r esist ance i s l ess t han 0. 060 o hms, so th e PS X h as a lo w v oltag e
drop even at high currents. Much bett er than detectors t hat u se a diode vo ltage drop.
Manual or Automatic Reset: Automatic reset of the breaker after 2 seconds. A sw itch can b e used for a
manual reset.
Power On/Off by DCC: Turn on/off output track pow er w ith your DCC Throttle!
Outputs for LED Indicators: LEDs can be added to monitor the input/output power and the status.
System R eset : CV63= 42 sets all CVs to origin al factor y values.
Output for Audio Alert: An audible sounder can be added to the card to alert if there is a short.
Network FeedBack: To Digitax Loco Net, NCE Cab Bus and Lens XpressNet for Shorted and Occupancy.
No Power Supply Needed: Board size: is 4.7 5 by 2.25 inch es
Flash Prog rammable: Micro Processor can accept updated softw are if nee ded.
Note: The PSX Circuit Bds are scribed and milled so you can separate into individual units if needed.
Note: The PSX
1 operates by opening one side of the two inputs leads when an overload is sensed. If you hav e a sit u ation
where both sides of the input line need to be opened on an overload, use the PSX
A
R auto reverser instead of the PSX
1.
The PSX
1 opens the path from J1
4toJ
2
2 when the breaker senses an over load. Additi onal power to the PSX
2, 3, & 4
is connected by daisy chaining from J1, 1 an d 2 to the next PSX J1, 3 and 4.
The PSX series includes 4, DCC Power District
Circuit Breakers that incorporate a solid state
design, block detection and network feedback.
PSX-1: 1 Block Control PSX-3: 3 Block Control
PSX-2: 2 Block Control PSX-4: 4 Block Control
There are (4) versions of the new PSX -AR Series:
Integrated DCC Circuit Breaker, Auto-Reverser and Stationery Decoder
(1) PSX-AR, w/ integrated Stall Motor Decoder
(2) PSX- ARFB, same as above has added network FeedBack
(3) PSX -ARS C, w/ integrated Snap Coil Decoder
(
4
)
PSX-ARSCFB
,
same as abo ve has added network FeedBack.
DCC
Not for DC, Analo
g
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - 1,2,3,4 Series (Rev:J, 5/11)

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com 1 of 10The PSX-1,2,3,4 Se

Seite 2 - *Instructions by Don Fiehmann

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com 10 of 10Sequential Progra

Seite 3 - PowerShieldX-1,2,3,4Wiring:

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com 2 of 10*Instructions by D

Seite 4 - Wiring Connections :

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com 3 of 10J7 Auto/Manual Res

Seite 5

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com 4of 10Wiring Connections

Seite 6 - CV Settings: Optional

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com Page 5 of 10The Table to

Seite 7 - Tri p Cu rr en t J ump er s

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com Page 6 of 10Setting Addre

Seite 8 - User Guidelines:

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com Page 7 of 10CV49–sets the

Seite 9 - Quick Start

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com Page 8 of 10Power Shields

Seite 10 - Lenz: Using the LH100:

DCC Specialties, 57 River Rd, Suite 1023, Essex Jct., VT. 05452 800-671-0641, [email protected] www.dccspecialties.com 9 of 10Before w iring ple

Kommentare zu diesen Handbüchern

Keine Kommentare