When recording signals with sharp transients drums and percussion, for example many engineers do not
mind occasional 1 to 3 consecutive sample overs (in fact, some record with overs on purpose!). Remember that
one sample is a very short period of time. Often 1 or 2 consecutive clipped transient samples will not neces-
sarily be apparent. One reason to avoid having the threshold set at 1 sample in these situations is so that the
engineer is not persuaded to lower the recording level to tape/disk when the indicators are only registering
transient OVERs. On the other hand, during the mastering process, it is important not to register any OVERs in
order to avoid problems at the pressing plant.
The chart below shows the position of DIP switches 6 and 7 for different consecutive sample thresholds.
DIP 6 DIP 7 # of consecutive OVERs
needed to illuminate OVER LEDs
down down 4
up down 3
down up 2
up up 1
External Settings
Calibration Mode (Meter Zoom)
Press & Hold the SOFT LIM button to enter Calibration Mode. The SOFT LIM LED will flash. In this mode, the
meter scale reads from 20 dBFS (bottom LED) to 11 dBFS (top LED), ie one LED per dB, and the OVER LED
illuminates when the level is within ±0.1 dB of the indicated value. CAL mode only affects the meters, and can
thus be used whether metering the A/D or D/A, in any operational mode.
D/A Calibration
The D/A converter can be calibrated over a wide range of likely operating values. It is calibrated from the fac-
tory so that an incoming digital signal at 16dBFS produces a level of +4dBu at the analog outputs. So, for
example, if you wanted the D/A converters to output a hotter (louder) signal at the analog outputs, you would
feed the digital input a level under 16dBFS (for example, 18dBFS) and calibrate the outputs until the analog
output level read +4dBu. Likewise, if you wanted a lower DAC output, you would feed the unit a 14 dBFS sig-
nal, for example, and calibrate the DAC accordingly. On the next page are brief instructions on how to calibrate
the D/A and A/D converters.
PSX-100 Users Manual
Page 19
As set at the factory, a digital signal at
16dBFS produces a level of +4dBu at the
analog outputs.