METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-53 Revision 4 : 05/09/12
Metro Baseline Re-Baseline: 04/29/10
9.4.2.19.2 Equipment Location
Signal equipment shall be located along the wayside only where necessary. All other
equipment shall be located on the outer edge of the right-of-way, in easily accessible
equipment housings.
Signal houses shall be provided with a fire and intrusion detection system.
Signal masts, grade crossing gates, flasher masts, cantilever signal masts and all concrete
signal structures shall follow CPUC GO 75 and City requirements for these structures.
9.4.2.19.3 Equipment Housings
All signal equipment housings shall include all required environmental controls to facilitate
maintenance and operation, including any necessary heating, ventilation and air
conditioning. The signal equipment shall be capable of operation in the event of a failure of
any environmental control subsystems. Houses, cases and junction boxes shall be steel or
aluminum. Signal houses and cases containing electronic equipment shall be coated with
reflective paint.
All equipment-housing openings shall be screened or sealed to prevent entry of animals and
insects to the extent practicable. All entryways shall be sealed following installation of
cables and wiring entering the housing.
All insulation material used to line the interior of equipment housing walls, doors and roofs
shall be flame retarding and non-electrically conductive, and shall not introduce a hazard of
any type.
Doors of housings shall be capable of being secured by a standard padlock and equipped
with a weatherproof seal.
All equipment housings shall be designed to accommodate possible future expansion of
equipment space by 30%.
9.4.2.19.4 Security of Equipment
All signal equipment housings, cases, junction boxes, switch mechanisms, and signals shall
be secured with an appropriate security device.
9.4.2.19.5 Maintainability
The signaling equipment shall be designed and constructed to facilitate quick and easy
troubleshooting and module replacement. The design shall require a minimum of testing
following module replacement.
Built-in indicators or meters shall be provided for routine maintenance, testing, and
diagnostic purposes. The use of plug-in devices, such as laptop computers for the
downloading of data from devices, including microprocessor interlockings, shall be allowed
in addition to a basic set of fault indicators. As a minimum, LED indicators shall be provided
for circuit boards to indicate the health status of a circuit board. A failed indication shall
signify to a maintainer that the board should be replaced.