METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-88 Revision 4 : 05/09/12
Metro Baseline Re-Baseline: 04/29/10
systems.
Vital microprocessor systems may be used.
The use of radio, land cable, or any combination, which forms a serial communication
channel for the signal system, shall not be considered vital in itself. Design techniques shall
be employed such that the equipment at each end of the communication link shall be
capable of detecting errors in the data transmitted and received, such that system operation
remains safe.
9.4.5.19 Materials and Equipment
9.4.5.19.1 General
Assemblies and components used to perform identical functions within the system shall be
mechanically and electrically interchangeable. Standard commercially available equipment
and material from multiple sources shall be used where practicable.
All wayside equipment shall be secured and protected by the use of tamper-resistant
covers. Where deemed appropriate by the Designer, further protection shall be provided
with intrusion detection devices.
All cables and wires shall be suitably protected. Conduits shall be provided under tracks,
along bridges and through roadways, to meet AREMA recommendations. All material and
equipment furnished shall be new and standard products of manufacturers regularly
engaged in the production of like equipment, and shall be the latest design, which complies
with the requirements of these Contract Documents.
9.4.5.19.2 Equipment Location
Signal equipment shall be located along the wayside only where necessary. All other
equipment shall be located on the outer edge of the right-of-way, in easily accessible
equipment housings.
Signal houses shall be provided with a fire and intrusion detection system.
9.4.5.19.3 Equipment Housings
All signal equipment housings shall include all required environmental controls to facilitate
maintenance and operation, including any necessary heating, ventilation and air
conditioning. The signal equipment shall be capable of operation in the event of a failure of
any environmental control subsystems.
All equipment-housing openings shall be screened or sealed to prevent entry of animals and
insects to the extent practicable. All entryways shall be sealed following installation of
cables and wiring entering the housing.
All insulation material used to line the interior of equipment housing walls, doors and roofs
shall be flame retarding and non-electrically conductive, and shall not introduce a hazard of
any type.
All equipment housings shall be designed to accommodate possible future expansion of